Our 33 Litre Front Loading Benchtop Autoclave, available in Classic and Autofill versions, is ideal for laboratory research and is low in water. Have a question about Autoclaves, Sterilizers or Steam Generators? Our FAQ page has the answers. All the machines are supplied with a user manual but sometimes it is not consulted! Astell offer training to operators, and this is a service I recommend to ensure.
Author: | Vigis Zoloshakar |
Country: | Kazakhstan |
Language: | English (Spanish) |
Genre: | Business |
Published (Last): | 5 July 2010 |
Pages: | 185 |
PDF File Size: | 20.41 Mb |
ePub File Size: | 4.91 Mb |
ISBN: | 171-6-73610-541-8 |
Downloads: | 8331 |
Price: | Free* [*Free Regsitration Required] |
Uploader: | Gardacage |
All stored details are printed, including Title, Temperatures, Times, and options settings. Keep it well away from any hot parts of the Sterilizer, do not allow to drape down the front and store in a dry place away from light or high temperatures. After the sterilizing stage is complete, water in the bottom of the chamber is expelled and then a post vacuum takes place, removing any remaining steam from the chamber and cooling the load.
Astell MXN – Series Autoclave programming instructions |
Mainly southern England Time in job: A copy of the original Manufacturers Manual and literature is also provided. Remove Key When not in use Some functions accessed with the key may concern operator safety. There are up to 8 Programs with a number of parameters which may be set. However, in most cases these products will need to be dry at the end of the cycle, and for this an Advanced Vacuum and Ashell Jacket will be necessary. The latter applies only to autoclaves with heaters in the chamber; an autoclave fitted with a steam generator will fill automatically and therefore will require a water supply.
The media will be kept warm for up to 48 Hrs. The power will be restored only when the temperature falls, and the controller will then behave as if the power had just been turned on. For Example, this allows a load to be placed in the chamber in the afternoon, which will start automatically before start of work next day. The ‘Swiftlock’ front loading range of autoclaves allows the user a greater choice of options unavailable on the smaller ranges, as well as easy loading access.
Autoclave service and maintenance – advice from the experts
Disregard any printed legends on the Printed Circuit Board that may suggest otherwise. Whilst it is possible to atell unwrapped simple and light fabric loads, they will come out saturated with water and sterility will be compromised. Open the control case and hinge the front forward.
Not all will show on all models. Note that this system is Active Only if program.
Do Not Use except for Safety-valve testing. A bacterial retentive filter is fitted to the exhaust ensuring nothing leaves the chamber without being sterilized filter may vary from that pictured.
At the end there is a delay as the new values are stored in permanent memory. The chamber will cool down more quickly than the load, so if the Programmable cooling lock is set to 99C the limiting factor will maunal the Preset Cooling Lock, This must be left set to astwll the worst-case Liquid load if the autoclave is used for liquids.
It is used by an engineer to monitor the operation of the pressure interlock system. This is useful for testing. Please keep a note of these displays ; You may be asked to quote these to assist the Astell service dept. One of the advantages of Astell is the history and experience within the company, meaning there is always an answer available somewhere!
Allows autpclave Astell Service Engineer remote access to the unit’s touchscreen controller, e. The operation of the assisted air cooling system is controlled via the colour touchscreen and is available on all models as autoflave additional option, except for those fitted with a vacuum.
A pump or Solenoid Valve feeds water to the chamber when the door is open before the beginning of the cycle.
autoclavve The time may be set using the Clock Setting section in the Supervisor “Options” An illustration of Paper Loading is at the back of this manual.
Once the reservoir is filled, this provides water for up to 15 cycles, and uatoclave acts as a collection vessel for condensate and the water that is automatically returned from the chamber at the end of each cycle, minimising water usage. A choice of 33, 43 and 63 litre models Self contained design with no installation required – just fill it with water and plug it in and the machine is ready to be used No mains water supply or drain necessary Fully programmable 5.
The Astell 120 – 344 Litre Front Loading Autoclave Range
Essentially this means any change made to a cycle, option, or device parameter will require an electronic user signature. What preventative measures do you recommend to prolong the performance of an autoclave?
There is a 30 second safety delay between pressing the “OPEN” Key and the bolt release which allows the door to be opened. You may now Start the Program Water Level Sensing The water level sensing system is designed to ensure sufficient water supply for a cycle and protects the heaters should excessive water loss occur.
Large front loading autoclave. Further details can be provided on request. The chamberis maintained at this temperature by the controller. If this display showsthe Float Switch sensor in the Water Tank has detected that the water level is too low, because the water supply to the tank is inadequate or has failed.